Aquarium Plants - Barr Report  
Go Back   Aquarium Plants - Barr Report > Barr Report > General Plant Topics
Reload this Page lighting for non-CO2 120G
General Plant Topics General Plant Topics and Aquatic Life discussions

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
lighting for non-CO2 120G
Old
  (#1 (permalink))
tedr108 is Offline
Lifetime Charter Member
Approaching Guru Status
Location: Los Angeles, CA
lighting for non-CO2 120G - 05-16-2008, 01:08 AM

Yes, I have been reading the "light intensity" thread under the Articles forum, but it isn't helping me make a decision. There seems to be a ton of variables in this lighting stuff.

I've been researching lighting for a 120G (48"x24"x24") non-CO2 tank. I'm fond of T5s, but they are rather strong for a non-CO2 tank, at least for the amount of area they cover. If 2 x 48" (54w) T5s covered more area (front and back), I would give that a try. I do not know much about T12s, T8s, T6s and the like -- but I am not immediately drawn to them from my research.

Anyway, I am now leaning toward 4 x 54w T5s and simply raising them up as high as necessary to reduce the light appropriately. I do the lights-hanging-from-conduit setup, so it would be very easy for me to adjust light height. I could also turn on 1 & 3 for half the day and 2 & 4 for the other half -- there are many options I could try with this. Other than wasting electricity and the extra cost, I feel that this would be a decent solution. Do you agree? If anybody has other possible ideas, I would enjoy hearing them.


Regards,
Ted

Last edited by tedr108 : 05-16-2008 at 02:03 AM.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#2 (permalink))
VaughnH is Offline
Lifetime Charter Member
Approaching Guru Status
 
VaughnH's Avatar
05-16-2008, 02:13 AM

Why install so much light you have to raise them high and waste the light by lighting up the floor? For a non CO2 tank I doubt that more than 2 of those T5 lights are desirable. If you space them properly they will cover the whole tank.


Hoppy
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#3 (permalink))
tedr108 is Offline
Lifetime Charter Member
Approaching Guru Status
Location: Los Angeles, CA
05-16-2008, 02:38 AM

That is good news for me, Hoppy. If 2 of the T5s will do the trick, all the better ... easier to build the fixture, cheaper, less waste. This was actually my first plan, not sure how I started thinking that only 2 of the T5s wouldn't give me enough coverage. Anyway, that's why I asked. Thank you.


Regards,
Ted
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#4 (permalink))
Tom Barr is Offline
Administrator
Admin
 
Tom Barr's Avatar
05-16-2008, 03:42 PM

2-4 would be okay, 4 is on the high side, 2 on the low side.
2 would run a 75 gal nicely, 4 and CO2 would be nice also.
Depends on plant choice also.

also, you will need to space the lights way apart to get decent coverage in the tank, say 16-18" apart with two, whereas 4-5" spacing works well with 4.
Also, run the 2x54 for 10 hours and the 4x54 for 2 hours etc.

You have some options.
On decent sized non CO2 tanks, and low light CO2 tanks, T5's are ideal.

Regards,
Tom Barr
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On

Points Per Thread View:
Points Per Thread:
Points Per Reply:



Powered by vBulletin Version 3.6.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
LinkBacks Enabled by vBSEO 3.0.0 RC5


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69