Solenoid valve placement?
Old
  (#1 (permalink))
magicmagni is Offline
Prolific Poster
Poster
Location: SF Bay Area
Solenoid valve placement? - 01-10-2006, 09:13 PM

I don't think that it would matter, but I want to use a solenoid valve after a needle valve. I understand the conventionally one would run it before and while that is a possibility it would be less work, and cleaner to run it after the valve.

So has tried this before or know a reason why it would not be a good idea to do this?

Thanks
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: Solenoid valve placement?
Old
  (#2 (permalink))
Cornhusker is Offline
Guru Class Expert
Poster
Re: Solenoid valve placement? - 01-10-2006, 10:41 PM

i just received shipment of an inline solenoid today.have eheim regulator and no other way to install a solenoid.btw this regulator has been in service for four years and has operated flawlessly.but now i want use the mist idea and need a way to shut off co2 and also to save on gas.i'll let you know how things work out. regards,cornhusker
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: Solenoid valve placement?
Old
  (#3 (permalink))
Tom Barr is Offline
Administrator
Admin
 
Tom Barr's Avatar
Re: Solenoid valve placement? - 01-11-2006, 12:16 AM

There are 2-4 reasons why not to do this.

The needle valve can leak and be jarred by the pressure changes.
You cannot control other tanks if you use more than one needle valve without adding individual solenoids as well.

One solenoid right after the regulator will control all the subsequent needel valves that you may have, not an issue if you only have one CO2 enriched planted tank.

The other reason is that unless the system is hard plumbed with copper/brass etc piping that will not leak at all, the CO2 tubing used to connect the needle valve to the solenoid will also leak out a lot more CO2 than normal since it's always under pressure.

I hard pipe my solenoids to the regulator, then add needle valves directly from this. This reduces the pressure and the jarring on the needle valves and CO2 lines.

I've done what you are thinking about, but mainly with yeast DIY set ups and I use the open function to vent off and stop CO2, rather than add it with the DIY set up.

Regards,
Tom Barr
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: Solenoid valve placement?
Old
  (#4 (permalink))
Cornhusker is Offline
Guru Class Expert
Poster
Re: Solenoid valve placement? - 01-11-2006, 05:12 PM

Magicmagni,most co2 setups nowadays come with regulator,solenoid,and needle valve.this is best. the eheim i have is my first setup for press. co2. did not know any better,(very expensive at the time).it has a connection adapter,(german to usa) gas bottle.it would be a kobbled job to try to set a solenoid between regulator and bottle.therefore someone told me of an inline solenoid that would serve my purpose.so far its working good,only time will tell. regards,cornhusker
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: Solenoid valve placement?
Old
  (#5 (permalink))
magicmagni is Offline
Prolific Poster
Poster
Location: SF Bay Area
Re: Solenoid valve placement? - 01-14-2006, 08:02 AM

Thanks for the replies.

I actually have one of those JBJ all in ones on my 120gallon. Nice setup, but this one I'm referring to here is a little project that I am working on for a 10 gallon tank. It's running 24/7, but I really need to get the solenoid on there as not to waste the Co2 at night especially since I don't have the luxury of a 5lbs Co2 tank for this one.

Those are good points Tom.

Where's a good place to get the hardware then to go from my regulator to the solenoid. This is the regulator I am using. Are most solenoids also 3/8"?

http://www.lelandltd.com/products/reg_spec.html
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: Solenoid valve placement?
Old
  (#6 (permalink))
matpat is Offline
Subscriber
Poster
Location: Dayton, Ohio
Re: Solenoid valve placement? - 01-14-2006, 05:54 PM

When I converted my beverage regulator to aquarium use, I just made a trip to my local welding store. They were very helpful and had the 1/4" to 1/8" reducer I needed. I would imagine they would have a 3/8" to 1/4" reducers and 1/4" to 1/8" reducers in stock. They were cheap by the way, les than $1.


Matt

South Western Ohio Aquatic Plant Enthusiasts (SWOAPE) member
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: Solenoid valve placement?
Old
  (#7 (permalink))
magicmagni is Offline
Prolific Poster
Poster
Location: SF Bay Area
Re: Solenoid valve placement? - 01-17-2006, 07:29 AM

Right on! I actually found a source online that had everything I needed in one shot without a lot of fuss and really good prices so I think I'm set. I'll have to post some pics of the setup when it is complete.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: Solenoid valve placement?
Old
  (#8 (permalink))
srozell is Offline
Guru Class Expert
Poster
Re: Solenoid valve placement? - 01-17-2006, 06:29 PM

Quote:
Originally Posted by magicmagni
Right on! I actually found a source online that had everything I needed in one shot without a lot of fuss and really good prices so I think I'm set. I'll have to post some pics of the setup when it is complete.

Post the source too please! It could be one we've missed!
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: Solenoid valve placement?
Old
  (#9 (permalink))
magicmagni is Offline
Prolific Poster
Poster
Location: SF Bay Area
Re: Solenoid valve placement? - 01-25-2006, 01:12 AM

I have been working with Rex Grigg on this one. I'm sure a lot of folks know him. He is on planted tank forums and can get pretty much get anything Co2 related and will even assemble the whole rig for you. He does those DIY in-line reactors as well for people I understand.

his site:

http://rexgrigg.com/./sale.html
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On

Points Per Thread View:
Points Per Thread:
Points Per Reply:

Similar Threads
Thread Thread Starter Forum Replies Last Post
Solenoid - closed or open? bogongmoth General Plant Topics 8 06-17-2006 07:25 AM
Spraybar placement for the mist method metasyntax General Plant Topics 0 06-06-2006 01:58 AM
Aquatic Ecosystems needle valve darren_in_the_marsh General Plant Topics 3 04-08-2006 08:23 PM
needle valve hadog General Plant Topics 4 08-01-2005 05:59 AM
Solenoid JadeButterfly General Plant Topics 3 02-05-2005 02:53 AM



Powered by vBulletin Version 3.6.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
LinkBacks Enabled by vBSEO 3.0.0 RC5


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69