CO2 Regulator Problem????
Old
  (#1 (permalink))
Dick is Offline
Junior Poster
Poster
CO2 Regulator Problem???? - 12-18-2005, 05:41 PM

I recently added a solenoid to my pressurized CO2 system. The regulator is set at and maintains 15 psi while the solenoid is on. When the solenoid shuts off, the gauge shows 25 psi and maintains 25 psi until the solenoid turns on and then bleeds down from 25 to 15 psi which is then maintained. I get a burst of bubbles in the bubble counter when the solenoid turns on,

Is this normal? Do I have a problem with my regulator?

Thanks

Dick
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: CO2 Regulator Problem????
Old
  (#2 (permalink))
metasyntax is Offline
Junior Poster
Poster
Location: Richmond Hill, Ontario, Canada
Re: CO2 Regulator Problem???? - 12-18-2005, 06:07 PM

The welding place I got my regulator from said that below 20-25psi, the guage was not accurate, and might fluctuate quite a bit. I would consider increasing the psi to 25, if you can, to see if that makes a difference.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: CO2 Regulator Problem????
Old
  (#3 (permalink))
VaughnH is Offline
Lifetime Charter Member
Approaching Guru Status
 
VaughnH's Avatar
Re: CO2 Regulator Problem???? - 12-18-2005, 10:31 PM

When I was working, several years ago, I worked a lot with various regulators. None of them do well without some minimum flow rate thru them. I was surprised to find that we can control flow at 1 bubble per second using a regulator. That is surely at the very lower limit where the regulator accurately controls pressure. So, I am not surprised that a regulator would let the pressure go up a bit with no flow. I agree that using a higher set pressure would be beneficial, but I would still expect to see the pressure change a bit when the outlet is shut off. I will have my CO2 set up going tomorrow, so I will see if I have the same result.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Re: CO2 Regulator Problem????
Old
  (#4 (permalink))
Dick is Offline
Junior Poster
Poster
Re: CO2 Regulator Problem???? - 12-18-2005, 11:12 PM

Thanks for the comments on setpoint pressure and regulator behavior. I'll be intereseted to hear if you get the same pressure increase when the solenoid is off!
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On

Points Per Thread View:
Points Per Thread:
Points Per Reply:

Similar Threads
Thread Thread Starter Forum Replies Last Post
CO2 regulator question stonecutter50 General Plant Topics 8 02-19-2006 06:25 PM
CO2 Mist "Problem" VaughnH Advanced Strategies and Fertilization 6 01-10-2006 03:14 AM
O2 regulator on CO2 pfgrobler General Plant Topics 1 09-24-2005 06:17 PM
co2 regulator up to par? brad General Plant Topics 8 08-17-2005 07:16 PM
co2 problem Cornhusker General Plant Topics 2 05-05-2005 12:05 PM



Powered by vBulletin Version 3.6.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
LinkBacks Enabled by vBSEO 3.0.0 RC5


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69