Aquarium Plants - Barr Report  
Go Back   Aquarium Plants - Barr Report > Barr Report > CO2 and Aquatic Plant Fertilization
Reload this Page Tank circulation via linked spraybars?
CO2 and Aquatic Plant Fertilization CO2 and Aquatic Plant Fertilization

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
Tank circulation via linked spraybars?
Old
  (#1 (permalink))
Gerryd is Offline
Lifetime Charter Member
Approaching Guru Status
Location: South Florida
Tank circulation via linked spraybars? - 08-16-2008, 06:39 PM

Hey all.

After reading the recent thread by Tom re: the c02 meter and the amount of variation of c02 levels in the tank, plant beds, etc, I was thinking of trying the following for better tank distribution of c02 and flow.

I know others use spraybars in their tanks.

Tank dimensions 72x24x24.

Basically I would create a 3 sided frame of connected spraybars that would have 3 vertical levels. The 3 sided frame would cover the back and both sides. The levels would be at 6" vertical levels, 6", 12" and 18".

I would connect the frame to my twin outflows to power it, so to speak.

The spraybar sections would/could be turned in slightly different directions to point up, down, straight, etc.

I was thinking that this would provide flow in just about ALL sections of the tank, especially those where I tend to plant heavily, backs and sides. This would also push towards the front and middle of the tank somewhat.

Then maybe a powerhead of two at each end to push the flow from the frame, across the front of the tank.

It would take quite a few sections of spraybar and connectors, but it SEEMS like it would work.

Before I buy 800 feet of spraybar and connectors, do you guys think this is viable?

My only real concern is with the size of the spraybar holes and how much flow/pressure I would need to drive through the frame adequately AND UNIFORMLY.

I wouldn't want the areas closer to the flow for example to get good flow and the most remote sections get nothing.

Thoughts?

Am off to surf for what I would need to put this together....

Thanks,


Gerry.

Last edited by Gerryd : 08-16-2008 at 06:44 PM.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#2 (permalink))
midazolam is Offline
Subscriber
Poster
08-16-2008, 08:59 PM

Quote:
Originally Posted by Gerryd View Post
Hey all.

After reading the recent thread by Tom re: the c02 meter and the amount of variation of c02 levels in the tank, plant beds, etc, I was thinking of trying the following for better tank distribution of c02 and flow.

I know others use spraybars in their tanks.

Tank dimensions 72x24x24.

Basically I would create a 3 sided frame of connected spraybars that would have 3 vertical levels. The 3 sided frame would cover the back and both sides. The levels would be at 6" vertical levels, 6", 12" and 18".

I would connect the frame to my twin outflows to power it, so to speak.

The spraybar sections would/could be turned in slightly different directions to point up, down, straight, etc.

I was thinking that this would provide flow in just about ALL sections of the tank, especially those where I tend to plant heavily, backs and sides. This would also push towards the front and middle of the tank somewhat.

Then maybe a powerhead of two at each end to push the flow from the frame, across the front of the tank.

It would take quite a few sections of spraybar and connectors, but it SEEMS like it would work.

Before I buy 800 feet of spraybar and connectors, do you guys think this is viable?

My only real concern is with the size of the spraybar holes and how much flow/pressure I would need to drive through the frame adequately AND UNIFORMLY.

I wouldn't want the areas closer to the flow for example to get good flow and the most remote sections get nothing.

Thoughts?

Am off to surf for what I would need to put this together....

Thanks,

While thats a creative approach, I think as with a lot of things in life we have to ask to what ends? If you can achieve adequate growth through conventional means (which certainly many people do) what would be the purpose of such a device. As an intellectual pursuit...a real life solution to a theoretical problem...I understand. As a lazy person, I say why bother
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#3 (permalink))
Gerryd is Offline
Lifetime Charter Member
Approaching Guru Status
Location: South Florida
08-16-2008, 09:15 PM

Hey,

Quote:
to what ends?

1. Better and more uniform flow brings more nutrients (including c02) to the plants and washes away debris and waster products.

2. Better plant growth overall and thus less algae.

3. Aesthetics as the frame would be BEHIND the plants for the most part.

4. Possible removal of extra powerheads currently required to help reach these 'dead' zones or areas of less flow and current. This would enhance #3.

Quote:
achieve adequate growth through conventional means

I am looking for better growth overall. I have 'adequate' and am shooting for higher that's all. Just thinking outside the box a bit and experimenting............


Gerry.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#4 (permalink))
jeff5614 is Offline
Subscriber
Poster
08-17-2008, 12:41 AM

I think it sounds like an interesting idea. I look forward to hearing your results and seeing the setup if you decide to give it a go.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#5 (permalink))
jeremy v is Offline
Guru Class Expert
Valued Contributor
08-17-2008, 03:55 AM

What about taking the same idea except making a loop that goes around the entire tank edge on the inside underneath the substrate. Then add t-fittings every 6" on that loop and make the third leg of the "T" female threaded and mounted so it point directly upwards. Then put small PVC threaded plug caps into each of the t-fittings. Now you have a nice loop manifold that is completely hidden beneath the substrate, and since it makes a complete loop the water pressure will remain pretty even throughout.

Now that you have the main structure, make a bunch of 12-18" long pieces of PVC with a male thread on one end and a cap on the other, and drill holes along the length at evenly spaced intervals for your spray bar holes. Now you can install these vertically by digging slightly into the substrate wherever there is a t-fitting on the main manifold. Remove the male threaded cap from the T-fitting and replace it with your new spray bar pipe. This way you can choose where your spray bars are located at any time and you can make sure that the spray bars are always hidden behind plants. You can also easily change things around as your aquascape changes.

Since the spray bars run vertically it also allows you to rotate the spray holes different horizontal directions instead of vertical directions. That might be better for achieving proper flow around the tank and plants. You can make the verticals different lengths as well if desired to keep them out of sight over the top of shorter plants as well. With this setup you can easily adjust for proper total flow and pressure through the spray bars by adding or subtracting a few vertical spray bars to the whole setup.

It is just an idea, but it might allow you a lot more freedom and ability to hide everything while still giving you the capability you are seeking.

Have a good one, Jeremy

P.S.- Another benefit to having the spray bars run vertically is that if you adjusted all the spray bars just a little bit the same direction (i.e all slightly clockwise or counter clockwise), all stray currents would combine together to create a slow circular current in the entire tank in addition to the individual smaller flows. You wouldn't really be able to do that with spray bars that are run horizontally.

Last edited by jeremy v : 08-17-2008 at 04:00 AM.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#6 (permalink))
Gerryd is Offline
Lifetime Charter Member
Approaching Guru Status
Location: South Florida
08-17-2008, 05:47 PM

Jeremy,

I like your idea as well.

If making a 4 sided rectangular frame, I would NOT use any T in the front section.

I doubt I would add a vert or two in the front lol

1. What size PVC would you use for the frame and verticals? 1/2 is easier to hide. I have a 3/4 loc-line now. I think 1/4" would be too restrictive of flow????

2. I was thinking 1/8" drilled holes for the spraybars. Thoughts??

Other thing is to find non-white PVC. Grey or black will blend in better with my black flourite substrate and my black background......I know it exists, but white is predominant........

Thanks for the thoughts.

Off to home depot to see what it would take...........


Gerry.

Last edited by Gerryd : 08-17-2008 at 05:53 PM.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#7 (permalink))
VaughnH is Online
Lifetime Charter Member
Approaching Guru Status
 
VaughnH's Avatar
08-17-2008, 06:08 PM

I think the total area of the holes in the spraybar should be a bit less than the cross section area of the tube. That makes them pretty small, but if they are much larger, most of the flow will be from the holes closest to where the incoming flow is. However, I still believe a flow slot works better than flow holes. But, that makes the maximum lenght of the spray bar be around 3 inches for a half inch ID tube inlet.


Hoppy
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#8 (permalink))
Gerryd is Offline
Lifetime Charter Member
Approaching Guru Status
Location: South Florida
08-17-2008, 06:52 PM

Vaughn,

What is a flow 'slot'? Is it just a cutout section in the pipe as opposed to numerous holes?

Could you help me understand your comment here?

Quote:
But, that makes the maximum lenght of the spray bar be around 3 inches for a half inch ID tube inlet

I just spent < $10 on all the PVC, elbows, etc I need to make this.

I will build the frame and the verts to scale to see how it looks.

I was concerned about flow out of the holes closest to the input as well.

Can I drill smaller holes closer to the source and go a bit larger further away?

Appreciate your thoughts.

EDIT:

I built the frame and input pipes. I still need more vertical pipe (10' was not enough lol) and then need to either drill or use a slot as Vaughn suggests.

I used slip T instead of threaded.....

I may add some more T's later.

Here is a link to a couple of pics of the frame. Just missing the rest of the vertical pipes and the drilling.

Image of Full frame - Photobucket - Video and Image Hosting


Gerry.

Last edited by Gerryd : 08-17-2008 at 07:35 PM.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#9 (permalink))
VaughnH is Online
Lifetime Charter Member
Approaching Guru Status
 
VaughnH's Avatar
08-18-2008, 12:48 AM

By a "flow slot" I meant using a small Dreml saw blade to cut a slit along the length of the tube. But, the area of that slit shouldn't exceed the cross section area of the inside of the tube, to keep flow coming out the whole length of the slit. Since about .06 inch is the smallest practical slit width, the area of that slit would exceed the ID area of the tube if the slit is much more than 3 inches long.

I found that tiny holes tend to get plugged up pretty quickly, with biofilm. Clearing them out was a major problem for me, and the spray bar didn't seem to be giving as much circulation as I had without it. That is when I switched to the flattened cone type outlet with a slit opening. It works much better for me.


Hoppy
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#10 (permalink))
Tom Barr is Offline
Administrator
Admin
 
Tom Barr's Avatar
08-18-2008, 02:06 AM

You should be able to make one for about 10-20$ and about 30 minutes.
CPVC 1/2" will do nicely.

I use to use these for RFUG's.............but they could be mounted on the rear, or even add CO2 under the gravel I suppose, some did that in the past.

You simply make a large grid out of the CPVC and add lots of flow through it.

Regards,
Tom Barr
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On

Points Per Thread View:
Points Per Thread:
Points Per Reply:



Powered by vBulletin Version 3.6.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
LinkBacks Enabled by vBSEO 3.0.0 RC5


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69