Aquarium Plants - Barr Report  
Go Back   Aquarium Plants - Barr Report > Barr Report > CO2 and Aquatic Plant Fertilization
Reload this Page Can needle valves go bad?
CO2 and Aquatic Plant Fertilization CO2 and Aquatic Plant Fertilization

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
Can needle valves go bad?
Old
  (#1 (permalink))
Roman is Offline
Lifetime Charter Member
Poster
 
Roman's Avatar
Location: Dragomelj, Slovenia (EU)
Can needle valves go bad? - 10-11-2006, 08:20 AM

I'm not sure what's going on with my needle valves.
I distribute CO2 from one bottle to 2 tanks and I set valves to specific bubble rate. Later I found that bubble rate dropped and drop is quite significant, 1/3 even 1/2 of initially set.
I even tried to set bubble rate higher and next day it dropped to wanted rate, but one day later it dropped even further
Happens to both bubble counters. Pressure before needle valves is 2 psi.
I checked for any leaks and found none. System is turned off at night, but didn't found any correlation with that.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#2 (permalink))
matpat is Offline
Subscriber
Poster
Location: Dayton, Ohio
10-11-2006, 01:41 PM

I have had similar problems with needle valves in the past. What has worked for me was to close the needle valve then open it to full flow (if you are using a diffuser make sure to remove it before turning up the flow), then adjust it back down to whee you want it. In my experience, it seems that something causes a blockage in the needle valve and cranking the CO2 up for a second blows it out.

I have also had luck by increasing the pressure on my regulator when changing from a single needle valve setup to a multiple needle valve setup.


Matt

South Western Ohio Aquatic Plant Enthusiasts (SWOAPE) member
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#3 (permalink))
VaughnH is Offline
Lifetime Charter Member
Approaching Guru Status
 
VaughnH's Avatar
10-11-2006, 05:25 PM

I think the problem is the 2 psi pressure at the needle valve. With such a low pressure, the flow through the valve is dependent on a lot of factors other than the geometry of the flow passage. And, those factors are not stable, so the flow changes. I found I got much better results with a pressure around 20 - 30 psi at the needle valve, even though adjusting the valve is very difficult, with my cheap Milwaukee regulator, compared to at a lower pressure.


Hoppy
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Needle Valve
Old
  (#4 (permalink))
angels is Offline
Junior Poster
Poster
Needle Valve - 10-11-2006, 05:45 PM

May want to check out Rex's Guide to Planted Tanks for CO2 supplies. VERY pleased with his needle valves, check valves.
Angels
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#5 (permalink))
Roman is Offline
Lifetime Charter Member
Poster
 
Roman's Avatar
Location: Dragomelj, Slovenia (EU)
10-11-2006, 08:47 PM

Quote:
Originally Posted by VaughnH View Post
I think the problem is the 2 psi pressure at the needle valve.

Ah, not psi it's bar. Preassure is 2 bars. That's enough preassure I think.



I'm from Europe, doubt Rex stuff would be compatible with my system
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#6 (permalink))
VaughnH is Offline
Lifetime Charter Member
Approaching Guru Status
 
VaughnH's Avatar
10-11-2006, 09:36 PM

Quote:
Originally Posted by Roman View Post
Ah, not psi it's bar. Preassure is 2 bars. That's enough preassure I think.
I'm from Europe, doubt Rex stuff would be compatible with my system
I agree. Two bars should be enough pressure. Now it sounds like bad needle valves.


Hoppy
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Old
  (#7 (permalink))
Tom Barr is Offline
Administrator
Admin
 
Tom Barr's Avatar
10-12-2006, 02:22 AM

A good valve is a happy thing and a very critical part of any system using CO2 gas.

Seek a good one.

Regards,
Tom Barr
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On

Points Per Thread View:
Points Per Thread:
Points Per Reply:



Powered by vBulletin Version 3.6.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
LinkBacks Enabled by vBSEO 3.0.0 RC5


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66