View Full Version : CO2 Regulator, blown gauge???
AquaCamp
08-03-2010, 02:49 AM
Does the gauge on the left look blown? Or is it supposed to be that far below 0?
http://www.plantedtank.net/forums/pHosting/f/2073_Gaugec.jpg
Thanks,
Ric
pat w
08-03-2010, 03:41 AM
It's been my experience (limited) that guages are nonlinear beasts and are calibrated to be most accurate @ 20% (400 psi here) and 80% (1600 psi). If they read accurate at 0 and full scale, well, that's just gravy.
Is that the guage for tank pressure? If no, you need a different guage.
If so, is the tank valve open feeding gas to the reg.? If closed I wouldn't care as long as it seems to read correctly when gas pressure is applied.
Is this a rebuilt or costom built reg? The guages seem to be wrong based on mine. A pic of the other guage would be nice. And a little more info on why you are asking could help.
Gotta go to the plant floor now. Be back when I can.
Pat
shoggoth43
08-03-2010, 03:37 PM
Is the vane on the guage actually below the stop pin? If so, it looks blown out to me if you're actually feeding gas to it.
-
S
Left C
08-03-2010, 06:10 PM
Do you also have an empty CO2 cylinder? I'd say that it's blow too. Like shoggoth43 mentioned, the vane shouldn't be below the stop bin.