Thread: High co2 level
View Single Post
Old
  (#3 (permalink))
terim is Offline
Junior Poster
Poster
11-17-2007, 06:46 PM

Quote:
Originally Posted by VaughnH View Post
Something isn't being measured correctly. Do you have 4 degrees KH, distilled or DI water in the drop checker? Is the KH you mentioned degrees of KH or ppm of KH? Is the GH degrees of GH or ppm of GH? What do you mean by "have the bubble counter at 30"?

The KH/GH test kit (from API) is in degrees. The direction for KH indicates one drop is equal to 1 dkh or 17.9 ppm it took 22 drops to get the result. It took 12 drops to get the result for GH and that equals 1 degree or 17.9 ppm. I didn't use distilled water in the drop checker, the directions from Red Sea said to use tap water. I will change it to distilled. As far as the bubble counter...I have it so that there is 30 bubbles per minute. Should I pick up a different test kit. I did the test twice with pretty much the same results.
  
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!