I don't think that is the best way to hook up the solenoid valve. When that valve is off, pressure downstream of the needle valve builds up to the low pressure setting of the regulator, 20-30 psi. Now, when the solenoid valve opens in the morning you get a blast of CO2 as the pressure rapidly drops to a couple of psi or less. That isn't good.
Hoppy
|